The content of chemical dosage often depends on the quality of wastewater, so when using it, we need to mix the chemicals in the appropriate ratio. Below is how to mix some chemicals.

Chemical warehouse of the company

How to mix chemicals

The estimated chemical requirements for the operation of the reactor are given here for reference only. The chemical dosage depends on the wastewater quality and should be reviewed and adjusted to achieve the best treatment results.

Caustic soda (NaOH)

The alkali (caustic soda flakes) used here is in its pure form for industrial use. In this project, caustic soda is used to neutralize and raise the pH of wastewater, mainly in the flotation tank.

Caustic soda tank: specialized composite tank with corrosion resistance.

Suitable caustic soda concentration for neutralizing wastewater is from 50 ppm.

Dosage of caustic soda needed: 50 ppm x 700m3 = 35 kg/day and night.

Note: Use only when there is a change in pH.

50% caustic soda solution

+ PAC alum

The alum used in this case is PAC (Poly Aluminum Chloride) in yellow powder or liquid form, highly soluble (MSDS).

Suitable alum concentration for coagulation reaction is about 250 ppm.

Alum dosage needed: 250 mg/lx 700 m3 = 175 kg/day and night.

Alum concentration should be about 10%.

PAC solution storage area

+ Javen

Dissolve the required amount of chemicals completely in 10 liters of clean water, mix only the amount needed and use as soon as possible after mixing. It is best to mix and use only on the same day, do not mix in advance for storage. The diluted chlorine disinfectant solution should be stored in a cool place.

10% javen solution 

 

+ Sulfuric Acid (H2SO4) 98%

In this treatment plant, sulfuric acid is used to neutralize and lower the pH of dye wastewater from a value of 9-11 to about 7-8, mainly in the intermediate tank.

The amount of acid needed is about 21 kg/day and night.

Acid tanks: specialized composite tanks that can withstand corrosion.

Suitable acid concentration for neutralizing wastewater is about 30 ppm.

The acid concentration required for simple dilution is usually 10%.

Mixed chemicals are converted to % concentration for easy calculation. Therefore, when mixing chemicals to treat wastewater, customers need to pay attention to the chemical dosage content of chemicals and wastewater to balance appropriately.

In addition, you can also call Loc Thien chemical company when you need advice. We are also the address for distributing quality industrial wastewater treatment chemicals at good prices throughout Ho Chi Minh City, Binh Duong, Dong Nai and other provinces.

When you need to buy the product or need advice on how to use it, please contact the hotline: Phone: (+84) 979 891 929  for the fastest support.

 

CONTACT US

Head Office : 452/6B Provincial Road 10, Binh Tri Dong Ward, Binh Tan District, Ho Chi Minh City

Phone: 028 6269 5669 – 028 6269 5662

Hotline: (+84) 979 891 929 VND 

Email: locthien@locthien.vn

Website: www.locthien.vn

www.hoachatcoban.net

Warehouse office branch:

Representative office: 140/53 Vuon Lai, An Phu Dong Ward, District 12, Ho Chi Minh City

Warehouse 1: Group 6, Phuoc Hung Hamlet, My Xuan Commune, Tan Thanh District, Ba Ria - Vung Tau Province

Warehouse 2: Phuoc Thai, Phuoc Binh Commune, Long Thanh District, Dong Nai Province

Warehouse 3: Tan Dong Hiep B Industrial Park, Di An, Binh Duong

Comments are closed